Thursday, September 27, 2012

Liquid Autoclave (STE-23L-A,class N)


Application Area:Dental Clinics, Human Hospitals, Laboratory, Veterinary, Beauty Salon, Tatoo...
Features:
.Class N autoclave, without vacuum pump, 
.STE-8L-A(Class N), STE-12L-A(Class N),STE-16L-A(Class N): Digital display.
STE-18L-A(Class N),STE-23L-A(Class N) LCD display.
.A built-in independent steam generator, making the sterilization fast and completely.
.Most of the main parts for TINGET autoclaves are imported from global famous company. 
.Sterilization temperature: 121。C/1.1bar, 134。C/2.1bar.
.Open-type water storage tank which is very easy for filling and cleaning.
.Automatic water filling and draining..
Safety:
.Door protection locking system prevents the cycle from starting unless the door is properly locked, and also prevents the door from openning if there have pressuer in the chamber.
.Pressure safety valves prevent over pressurizeation in chamber and generator.
.A safety fuses prevent over heating in the chamber and generator.
.Able to detect and identify the exact cause of any problem by warning and showing a specific error code.
.Water level switch in the water tank, controlling the max and min water level.
Documentation:
.Have printer port, able to be connected TINGET printer to print the sterilization records for each cycle.

Monday, September 24, 2012

Laser tattoo removal machine treatment principle


Laser removal tattoo machines treatment characteristics:Colorful LCD widescreen computer.Power adjustable, wide range of treatment.Unique cooling, so that working longer hours.Q-switched solid-precious stones, so that a single pulse width narrower.High security, light pain, does not damage normal skin, without leaving scars.The use of laser selective photothermolysis effect, so that instantly generate high-energy laser is absorbed by pigment particles, resulting in its expansion, rupture, while part of the pigment granules migrate to the surface with the skin is cleared, most run by macrophages to lymph nodes or re-macrophages. While the surrounding normal tissue, because they do not absorb the fixed-wavelength laser, not form any damage.

Initial jewelry: 18 to 10 standard size with a diameter from 5 / 16 to 1 / 2 of the charming ring inlaid with beads. Ring should be large enough to accommodate the swelling of the puncture site and can not be too close to the lips. When a puncture wound healing can be worn after the smaller ring. 16-10 standard sized lips decorative nails, Labret puncture hole length than the width of 1 / 8 to accommodate the swelling of the puncture site. Strongly recommend the use of female lips nail, tear or inflammation of the external thread can even have healing puncture. The edge of the disc is smooth. 18-10 standard size lip nails should be used 316L stainless steel or titanium alloy for medical, 14K, 18K gold-made products.

Hyaluronic Acid plastic price depends on the hyaluronic acid component of the most important number. Because hyaluronic acid is not simply the Long high plastic nose, the nose needs to take into account the tip of the nose, while also considering the different people have different height requirements nose, then the amount of hyaluronic acid are not used are different. However, under normal circumstances, hyaluronic acid hyaluronic acid plastic usually 1-2 teams better.

Friday, September 21, 2012

tattoo needle


tattoo needle with a difference, really good work on the main differences in the material on the same, outside some compare solder interface can clearly distinguish the production process for a tattoo. Good work to do needle neat fork out even more delicate color of the tattoo. The other hand can be seen to do something very obvious scratches pigment granules.

Tongue Ring is another name for piston rings, piston rings are generally made cast iron, a certain flexibility, cross-sectional variety of shapes, surface coating to increase running performance. When the engine is running, the piston will heat expansion, so the piston rings have open space, the installation in order to maintain sealing, piston ring of open space to the staggered position. A piston often have three to four rings, they are in accordance with the role of different gas ring and oil ring is divided into two categories.

Hyaluronic Acid, hyaluronic acid scientific name (Hyaluronic acid, referred to as HA) or said uronic acid, the disaccharide units (grape acid-N-B sulfur glucosamine) polymer composed of straight-chain polysaccharide, is an organization a naturally occurring substance. Widely exist in nature vertebrate connective tissue, mucous tissue, the eye's lens and the film clip of some bacteria, in the dermis of human skin plays an important role in the matrix, whether the overall organizational structure of the maintenance or is transported between cells have a very important function.

Wednesday, September 19, 2012

Celioscope Autoclave,STE-23L-T

Categories:
EN13060 Standard Class B Autoclave

Brand:
TINGET

Model:
STE-23L-T

Type:
Pressure Steam Sterilization Equipments

Chamber Volume:
25 Liter

Chamber Size:
Ø230×600

Power:
2200W

User Interface:
English, German, Spanish

Sterilization Programs:
10 programs

Testing Programs:
B&D , Helix, Vacuum

Update Time:
09-20-2012


Safety:

.Door protection locking system prevents the cycle from starting unless the door is properly locked, and also prevents the door from openning if there have pressuer in the chamber.

.Pressure safety valves prevent over pressurizeation in chamber and generator.

.A safety fuses prevent over heating in the chamber and generator.

.Able to detect and identify the exact cause of any problem by warning and showing a specific error code.

.Water level switch in the water tank, controlling the max and min water level.


Documentation:

.Have printer port, able to be connected TINGET printer to print the sterilization records for each cycle.

.Have USB prot, it is easily to connect the memory disk to save the sterilization records.

.Able to save about 20 sterilization cycles in the autoclave for the user checking and printing at any time.


Programs: 







Monday, September 17, 2012

Structural analysis of autoclave


Hyaluronic acid hyaluronic acid scientific name (Hyaluronic acid, referred to as HA) or said uronic acid, the disaccharide units (grape acid-N-B sulfur glucosamine) polymer composed of straight-chain polysaccharide, is an organization a naturally occurring substance. Widely exist in nature vertebrate connective tissue, mucous tissue, the eye's lens and the film clip of some bacteria, in the dermis of human skin plays an important role in the matrix, whether the overall organizational structure of the maintenance or is transported between cells have a very important function.

Autoclave-way sensing system monitors the air exclusion states: In order to avoid residual air affect the results of sterilization, the instrument sterilizer using two sensors to detect whether there is residual air.

Auto exhaust: using the latest device to automatically exclude the steam can reach without boiling for sterilization of liquid matrix; in the sterilization is completed, you can pre-set rate gradually release the steam.Autoclave is higher than atmospheric pressure, the boiling point of water up to temperatures above 100, and equipment sterilization of liquid or a pressure vessel.Autoclave electric lock system: just touch the controller can be easily and safely open the lid.Safety interlock device two-way test: by detecting pressure and temperature inside to lock the cover, ensure greater security when.

Agar approach: allows users to dramatically speed up the melting of more agar or inside to warm up.A variety of optional accessories: a variety of related accessories for the purchase (such as hanging baskets SUS sterilization, drug waste basket).Process status display: a set of flash sterilization process indicates the current variety of conditions.Autoclave function extension option: a buoy sensors, digital printers, automatic water supply unit and cooling unit.Automatic layout start the program: Built-in timer can be set for some time procedures, in order to automatically start a autoclave sterilization cycle (can be maintained up to one week). Bicarbonate hemodialysis memory (storage) support system: You can change various parameters (such as sterilization, exhaust, heating and other parameters), and in the event of change (or even a power failure) of these parameters can still be retained.Space-saving design: open the lid vertically upwards to save space.

Monday, September 10, 2012

How to Use an Autoclave

Is a high-pressure sterilization of medical and scientific equipment of the most effective method. Although at normal pressure simply boil water to kill most microbes and spores, it will not kill them. 1 atm reactor pressure or 15 pounds per square inch, which in turn raise the boiling point of water, water. Autoclave, then heated to boiling, the boiling point of the elevated temperature, at which point it is hot enough to kill all life forms, which in 15 minutes, sterilized equipment or equipment inside the water.

Explain
Drain valve on the control knob turned, autoclave, usually at the bottom of the front of the machine, to the closed position.

Open the door autoclave and hot water added to the bottom of this opening, filling, slightly below the reservoir lip. On most machines, which will require about 1 gallon of water.
Into the autoclave should be included in a shelf in the sterilization of the material. The liquid in the bottle should be 3 / 4 or less full, slightly loosening the lid. Clean up the dish should be installed at the top, loading plates agar-side down pollution, and instruments should be in brown paper, and binding to make sure it's introduced.

Close the door autoclave and long-handled according to its safety latch.
Switching exhaust switch, located at the top of the middle of most machines, if you are instruments of sterilization material, contains water, slow or quick exhaust exhaust
Twist the timer, select the appropriate length of time to disinfect. For small quantities of the machine, which is 15 minutes, the volume contains more than 1 liter, which is 30 minutes, 1 gallon or larger machines, you should choose a 60-minute cycle of the machine. This will start the machine.
Wait until the timer reads zero and the pressure indicator at the same time, and then open the door, pay attention to keep your hands, arms and face emerging from the doors of the upper part of the steam may burn you.

With sterile, heat-resistant gloves, remove the sterilized items. Any pollution into the melted agar, into the biohazard container immediately, then rinse with hot water glass.
Autoclave drain valve control torque to the open position empty water.

Friday, September 7, 2012

Teach you how to use a Autoclave

1, drain valve control knob twisted the bottom of the autoclave , usually located in front of the equipment, closed position.
2, opened the door, hot water kettle filled the bottom of this opening, it is just below the former reservoir on the lips. In most machines, which will take about a gallon of water.
3, the load material can be sterilized to the book on the shelf in the autoclave oven. Liquid in the bottle should be full, or less cover slightly relaxed. Clean dish should be installed in the top, pollution dish agar side down drunk, and instrumentation should be rolled in brown paper, and then nails to fix.
4, in the autoclave oven door closed and the pressure it is safe long-handled leash. 
5, switch, located in the middle of the exhaust at the top, most of the machine, if you are a slow discharge of water containing bactericidal materials, or to quickly exhaust the sterilization equipment.
6, the timer select the appropriate length of time for sterilization. Taiwan is a small machine for 15 minutes, the machine that contains one liter volume is 30 minutes, and large machines in 1 gallon or more size you should choose a 60-minute period. This starts the machine. 
7, until the timer and pressure indicators not only read zero, and then open the autoclave door, careful to keep your hands, arms and face away from the door of some place new and steam may catch fire.
8, using the sterile removal of disinfection, thermal stability of the gloves.

Tuesday, September 4, 2012

Autoclaves in medicine

medical autoclave is a device that uses steam to sterilize equipment and other objects. This means that all bacteria,viruses, fungi, and spores are inactivated. However, prions, like those associated with Creutzfeldt-Jakob disease, may not be destroyed by autoclaving at the typical 134 °C for 3 minutes or 121 °C for 15 minutes. Also, some recently-discovered organisms, such as Strain 121, can survive at temperatures above 121 °C.